Experiments results


Please enter your commented experiment results here:
as the following exemple with yeast before and after adding CCCP, or measurement of the both left and right palms


-Experiment Number: 1A
-type of PMT :R331-05 selected, Hamamatsu, Japan
-Distance detector to sample:
-Size of the active detector area:
-Scanned surface / sample surface : 9.6 cm^2
-Laboratory (location also): BPL SNU South Korea
-Operator : Frederic Laager F.Laager@gmx.ch
-Type of sample : Yeast Saccharomyces cerevisiae 0.507g dry weight + 3ul pure H20
-Age: N/A
-Filters used : none
-state of the sample : after 24 dark adaptation
-date of the measurement: 2007.2.8
-type of measurement : Sponteanous Emission
-DC average : 22.258 +/- 5.615 (not substrated to the data)
-Time gate : 1s
-Length of the measurement : 360s
-Publication : published in JOURNAL OF THE KOREAN SOCIETY OF JUNGSHIN SCIENCE
-Comments: None


-Experiment Number: 1B
-type of PMT :R331-05 selected, Hamamatsu, Japan
-Distance detector to sample:
-Size of the active detector area:
-Scanned surface / sample surface : 9.6 cm^2
-Laboratory (location also): BPL SNU South Korea
-Operator : Frederic Laager
-Type of sample : Yeast Saccharomyces cerevisiae 0.507g dry weight + 3ul pure H20 + 3ul of 10uM CCCP (sigma aldrich C2759)
-Age: N/A
-Filters used : none
-state of the sample : after 24 dark adaptation and adding CCCP
-date of the measurement: 2007.2.8
-type of measurement : Sponteanous Emission
-DC average : 22.258 +/- 5.615 (not substrated to the data)
-Time gate : 1s
-Length of the measurement : 720s
-Publication : published in JOURNAL OF THE KOREAN SOCIETY OF JUNGSHIN SCIENCE
-Comments: None


-Experiment Number: 2
-type of PMT :R331-05S, Hamamatsu Photonics, Japan
-Distance detector to sample:
-Size of the active detector area:
-Scanned surface / sample surface : 9.6 cm^2 2 times
-Laboratory (location also): BPL SNU South Korea
-Operator : Frederic Laager
-Type of sample : Homosapiens, male, Palm of the left and right hands
-Age: 25 years
-Filters used : none
-state of the sample : Normal condition
-date of the measurement: 2007.7.12
-type of measurement : Sponteanous Emission
-DC average : left : 1.118 +/- 1.43 right: 1.504 +/- 1.397310004 (not substrated to the data)
-Time gate : 100ms
-Length of the measurement : 180s
-Publication : Not published
-Comments: first column is left second is right


-Experiment Number: 3 exp_3.gif
-type of PMT : integrated H7360-02, Hamamatsu Photonics, Japan
-Distance detector to sample:
-Size of the active detector area:
-Scanned surface / sample surface : petri dish, 10cm diameter
-Laboratory (location also): LaFA, CESET/Unicamp, Limeira/SP`- Brazil
-Operator : Cristiano M. Gallep
-Type of sample : wheat seedlings (~150), mineral water (20mL)
-Age: < 1 year
-Filters used : none
-state of the sample : Normal condition
-date of the measurement: 2005. dez. 05th
-type of measurement : Sponteanous Emission
-DC average : 180counts/10s (not substrated to the data)
-Time gate : 10s
-Length of the measurement : ~72h
-Publication : GALLEP, Cristiano de Mello . Biophoton counting in cereal germination using a simple photon-counting system. In: Summer School 2006- Biophotons and Applications, 2006, Neuss. Proceed. of Summer School 2006- Biophotons and Applications, 2006. p. TU12.
-Comments: first column is time, second is counts/10s
A2005 05_12.txt


-Experiment Number: 4 exp_4.gif
-type of PMT : integrated H7360-01, Hamamatsu Photonics, Japan
-Distance detector to sample:
-Size of the active detector area:
-Scanned surface / sample surface : petri dish, 10cm diameter
-Laboratory (location also): LaFA, CESET/Unicamp, Limeira/SP`- Brazil
-Operator : Cristiano M. Gallep
-Type of sample : wheat seedlings (~150), mineral water (10mL), alcohol (10mL)
-Age: < 1 year
-Filters used : none
-state of the sample : Normal condition
-date of the measurement: 2005. dez. 03rd
-type of measurement : Sponteanous Emission
-DC average : 150counts/10s (not substrated to the data)
-Time gate : 10s
-Length of the measurement : ~62h
-Publication : GALLEP, Cristiano de Mello . Biophoton counting in cereal germination using a simple photon-counting system. In: Summer School 2006- Biophotons and Applications, 2006, Neuss. Proceed. of Summer School 2006- Biophotons and Applications, 2006. p. TU12.
-Comments: first column is time (s), second is counts/10s
A2005 03_12.txt

-Experiment Number: 5 exp_5.gif
-type of PMT : integrated H7360-02, Hamamatsu Photonics, Japan
-Distance detector to sample:
-Size of the active detector area:
-Scanned surface / sample surface : petri dish, 10cm diameter
-Laboratory (location also): LaFA, CESET/Unicamp, Limeira/SP`- Brazil
-Operator : PEREIRA, Cristiane Alves ; BATISTA, Daniella Cristina
-Type of sample : Yeast Saccharomyces cerevisiae in powder, water, and solutions of K2Cr2O7
-Age: fresh
-Filters used : none
-state of the sample : Normal condition and stressed by dicromate
-date of the measurement: May 2006
-type of measurement : Sponteanous Emission
-DC average : ~180counts/10s (not substrated to the data, available)
-Time gate : 10s, with average of 100 local points
-Length of the measurement : ~8h
-Publication : PEREIRA, Cristiane Alves ; BATISTA, Daniella Cristina ; GALLEP, Cristiano de Mello ; OLIVEIRA, Vanessa de Menezes ; ALMEIDA, Gilberto de ; OLIVEIRA NETO, Abílio Lopes de . “Avaliação Ecotoxicológica em meio aquoso através de emissão biofotônica de organismos-teste. In: IX CONGRESSO BRASILEIRO DE ECOTOXICOLOGIA, Ecotox - 2006
-Comments: first column is time (s), second is background counts, 3rd is for the sample with water, 4th to the last are for the samples with dichromate solutions (in this order 0.01, 0.02, 0.03, 0.035, 0.04 mg/L)
exp 5.txt


-Experiment Number: 6 Chi experiment 1.xls
-type of PMT : Electron Tubes 9235B
-Scanned surface / sample surface : Hand (right)
-Distance detector to sample: 10 CM
-Size of the active detector area: 52 MM
-Laboratory (location also): IIB
-Operator :Eduard van Wijk Meluna IIB [[mailto: (eduard_van_wijk@meluna.nl)]-Type of sample : Human-Age: 50-Filters used :NO -state of the sample : CHI-producing-date of the measurement: 29 juni-type of measurement : Sponteanous Emission-NO BG subtractction-Time gate : 0.05s-Length of the measurement : 6000-Publication : NO-Comments: R-01-REST R-02-PRODUCING chi R-03- REST R-04- REST R-05-PRODUCING chi R-06- REST R-07- PRODUCING chi R-08- REST R-09- PRODUCING chi R-10 REST R-11- PRODUCING chi R-12 REST


-Experiment Number: 7 Chi experiment 2.xls
-type of PMT :Electron Tubes 9235B
-Scanned surface / sample surface : hand
-Distance detector to sample: 10 CM
-Size of the active detector area: 52 MM
-Laboratory (location also): IIB
-Operator : Eduard van Wijk Meluna IIB [[mailto: (eduard_van_wijk@meluna.nl)]-Type of sample : Human-Age:50-Filters used : NO-state of the sample : Chi producing-date of the measurement: 14 okt-type of measurement : Sponteanous Emission-NO BG subtractction-Time gate :0.05ms-Length of the measurement :6000-Publication : NO-Comments:R-01-REST R-02-PRODUCING chi R-03- REST R-04- REST R-05-PRODUCING chi R-06- REST R-07- PRODUCING chi R-08- REST R-09- PRODUCING chi R-10 REST R-11- PRODUCING chi R-12 REST